Fabrication For A Set Of Sieves And Shaker

This research work on “Fabrication For A Set Of Sieves And Shaker” is available in PDF/DOC. Click the below button to request or download the complete material

Abstract

The fabrication of a set of sieves and shaker was carried out in paliton workshop, Enugu. After a thorough analysis on the suitable materials to be used in fabrication, galvanized steel was chosen due to its advantages over materials of fabrication. The fabrication was carried out in order to analyze the sizes of particles. The component parts of the sets of sieve and their dimensions are as follows:
Height of sieve 5.5cm
Number of sieves 7
Diameter of sieve 13.5cm
Shape of sieve circular
Height of sieve set 44cm
In fabricating this set of sieves, some factors were taken into consideration and they are:
The capacity of the sieve.
The type of mixture that can be filtered in it.
The types of properties and composition of the mixture.
The type of material to be used for fabrication of the sieve and shaker.
The mechanism of the filtration process and also,
The cost, which is the determinant, factor in fabrication of any equipment.
These factors help greatly in the fulfillment of the objective of this project study. And after fabrication the projects were tested and seem to be working very efficiently with a reasonable separation of particle and cut diameter.
Using the above dimensions, the following fabrication procedures were undertaken, layout, cutting, drilling, welding, filling sand papering, washing and painting, drying assembling.
Finally, the set of sieves and shaker were subjected to the process of washing, painting and drying.

 

 

 

 

Chapter One

INTRODUCTION
Generally, all engineering aspects involve fabrication more especially for chemical plants or equipment, which are used for several processes. This fabrication is carried out so as to achieve and put to practice chemical processes with the help of some components for equipment used for the fabrication procedures enables engineers to deal with operations for separating the component of a mixture, which is automatically based on particle size analysis of materials from one particular sieve to another.
Chemical engineering mostly deals with the fabrication of sieve among other fabrication in order to fulfil the theory of separation technique. In separation processes especially particle size analysis is where sieving technique are available.
During the operation of particle size analysis, many types of screen can be involves, which include Grizzy screens, Revolving screens, mechanical shaking screens, vibrating screen, electrically vibrated screens, oscillating screen, Reciprocating screens and Gyratory screens.
As this project involves the fabrication of set of sieves, it therefore requires good layout and easy separation of oversize and undersize in the contacting sieve unit.
Moreover, in the fabrication of set if sieves, we have to bear certain qualities in mind in which the set of sieves will have to portray such as determination of size and shape of the equipment, which contributes to the efficiency of the equipment. Among the above aim, the set of sieves should be considerable in terms of costing and also availability and portability of the set of sieve should be considered.
Above all, the set of sieve is fabricated in such a way that the particle of larger size than that of the sieve will be retained on the sieve while the particle of lower size will pass through the sieve and be collected on and9othet sieve as undersize, which is also separated by that sieve.

Table of Contents

Title page
Approval page
Letter of transmittal
Dedication
Acknowledgement
Abstract
Table of content

CHAPTER ONE
1.0 INTRODUCTION

CHAPTER TWO
2.0 LITERATURE REVIEW
2.1 Model
2.2 Screening
2.3 Types of screens
2.4 Screen surface
2.5 Factors in selecting screen equipment
2.6 Method of feed

CHAPTER THREE
3.0 MATERIAL OF CONSTRUCTION
3.1 Aluminum and aluminum alloy
3.2 Carbon and low alloys steel
3.3 Corrosion
3.4 Contact or galvanic corrosion

CHAPTER FOUR
4.0 FABRICATIONAL PROCEDURE
4.1 Layout
4.2 Cutting
4.3 Drilling
4.4 Welding
4.5 Filling
4.6 Sand papering
4.7 Washing and painting
4.8 Drying
4.9 Assembling

CHAPTER FIVE
5.0 OPERATION AND MAINTENANCE
5.1 Function of some parts of the electrically vibrated screen.

CHAPTER SIX
6.0 RECOMMENDATION AND CONCLUSION
6.1 Costing
REFERENCE

You May Like These Research Topics
Academic Research Structure: Important Sections

A 150–300 word synopsis of the main objectives, methods, findings, and conclusions of the Fabrication For A Set Of Sieves And Shaker should be included in the abstract.

Every chapter, section, and subsection in the research work should be listed in the Table of Contents, including the page numbers that correspond to each one.

The background, research question or hypothesis, and objective or aim of the Fabrication For A Set Of Sieves And Shaker should all be presented in the introduction, which is the first section.

A survey of previously conducted research on Fabrication For A Set Of Sieves And Shaker should be included in the literature review, together with an overview of the main conclusions, a list of any gaps, and an introduction to the current study.

The conclusion part should address the implications of the study, provide an answer to the research question and summarize the key findings.

The reference of Fabrication For A Set Of Sieves And Shaker, which should be formatted following a particular citation style (such as APA, MLA, or Chicago), is a list of all the sources cited in the title.

Other important sections of the Fabrication For A Set Of Sieves And Shaker should include the Title page, Dedication, Acknowledgments, Methodology, Results, Discussion, Appendices, Glossary, or Abbreviations List where applicable.