Design And Construction Of A Blown Fuse Indicator
This research work on “Design And Construction Of A Blown Fuse Indicator” is available in PDF/DOC. Click the below button to request or download the complete material
A fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby interrupting the current. It is a sacrificial device; once a fuse has operated it is an open circuit, and it must be replaced or rewired, depending on type. Generally, when equipment indicates no power, the cause may be just a blown fuse. Here is a blown fuse indicator circuit that shows the condition of fuse through LEDs. This compact circuit is very useful and reliable. It uses very few components, which makes it inexpensive too.
TABLE OF CONTENTS
COVER PAGE
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWELDGEMENT
ABSTRACT
CHAPTER ONE
1.0 INTRODUCTION
1.1 BACKGROUND OF THE PROJECT
- PURPOSE OF THE PROJECT
- AIM OF THE PROJECT
- OBJECTIVE OF THE PROJECT
- PURPOSE OF THE PROJECT
- LIMITATION OF THE PROJECT
- ADVANTAGES OF THE PROJECT
- PROBLEM OF THE PROJECT
- APPLICATION OF THE PROJECT
- RESEARCH QUESTION
- PROJECT ORGANISATION
CHAPTER TWO
LITERATURE REVIEW
- OVERVIEW OF THE STUDY
- REVIEW OF THE RELATED STUDY
CHAPTER THREE
3.0 CONSTRUCTION METHODOLOGY
3.1 BASIC OF THE SYSTEM
3.2 BLOCK DIAGRAM OF THE SYSTEM
3.3 SYSTEM OPERATION
3.4 CIRCUIT DIAGRAM
3.5 CIRCUIT DESCRIPTION
3.6 DESCRIPTION OF COMPONENTS USED
3.7 POWER SUPPLY UNIT
CHAPTER FOUR
4.0 TESTING AND RESULTS
- CONSTRUCTION PROCEDURE AND TESTING
- INSTALLATION OF THE COMPLET DESIGN
- ASSEMBLING OF SECTIONS
- TESTING OF SYSTEM OPERATION
- COST ANALYSIS
CHAPTER FIVE
- CONCLUSION
- RECOMMENDATION
- REFERENCES
KEYWORD: simple blown fuse indicator, blown fuse indicator project report pdf, blown fuse indicator car, blown fuse indicator project pdf, fuse holder with blown fuse indicator, electrical fuse, fuse failure indicator, fuse status indicator.
Blown fuse indicator operation
Under normal conditions (when fuse is alright), voltage drop in first arm is 2V + (2 x 0.7V) = 3.4V, whereas in second arm it is only 2V. So current flows through the second arm, i.e. through the green LED, causing it to glow; whereas the red LED remains off.
Fig.1 Blow- fuse indicator
When the fuse blows off, the supply to green LED gets blocked, and because only one LED is in the circuit, the red LED glows. In case of power failure, both LEDs remain ‘off’.
This circuit can be easily modified to produce a siren in fuse-blown condition (see Fig. 2). An optocoupler is used to trigger the siren. When the fuse blows, red LED glows. Simultaneously it switches ‘ON’ the siren.
Fig.2 Blow fuse indicator with alarm
Advertisement
In place of a bicolour LED, two LEDs of red and green colour can be used. Similarly, only one diode in place of D1 and D2 may be used. Two diodes are used to increase the voltage drop, since the two LEDs may produce different voltage drops.
A 150–300 word synopsis of the main objectives, methods, findings, and conclusions of the Design And Construction Of A Blown Fuse Indicator should be included in the abstract.
Every chapter, section, and subsection in the research work should be listed in the Table of Contents, including the page numbers that correspond to each one.
The background, research question or hypothesis, and objective or aim of the Design And Construction Of A Blown Fuse Indicator should all be presented in the introduction, which is the first section.
A survey of previously conducted research on Design And Construction Of A Blown Fuse Indicator should be included in the literature review, together with an overview of the main conclusions, a list of any gaps, and an introduction to the current study.
The conclusion part should address the implications of the study, provide an answer to the research question and summarize the key findings.
The reference of Design And Construction Of A Blown Fuse Indicator, which should be formatted following a particular citation style (such as APA, MLA, or Chicago), is a list of all the sources cited in the title.
Other important sections of the Design And Construction Of A Blown Fuse Indicator should include the Title page, Dedication, Acknowledgments, Methodology, Results, Discussion, Appendices, Glossary, or Abbreviations List where applicable.